TSDZ16 Configuration Tool
AI-generated image

Set up your TSDZ16 yourself.

A Windows program that reads the values of your TSDZ16 controller, changes them and writes them back. Each value comes with a description of what it does.

€49.95 incl. VAT
Buy now All settings

All settings

You can change these 26 values with the program. Factory is the value set at the factory, Range the permitted limits.

SettingFactory RangeWhat it does
Pedal pulses before motor start42 – 4 pulsesPulses from the cadence sensor before the motor starts. Fewer: the motor kicks in after a shorter crank movement. 2 is the minimum; the crank always has to turn forward a little.
Torque threshold above zero point16340 – 163 countsPedal pressure at which assistance starts. Lower: starts with light pressure. Too low: the motor pushes as soon as your foot rests on the pedal.
Torque increase per 50 ms305 – 30 countsHow fast the pedal pressure has to rise when you push off for the motor to start. Lower: the motor responds earlier.
Speed limit (0 = from display)06 – 99 km/hSpeed at which assistance ends. 0 = value from the display. Power is reduced from 88 % of the value. Above 25 km/h the bike is no longer a pedelec (registration, insurance).
Motor speed limit62005000 – 8000 Maximum motor speed. Limits assistance at very high cadence. Also applies to walk assist and throttle.
Voltage limit during overmodulation30003000 – 4095 of 4095How far the controller reduces the motor voltage when it reaches its voltage limit. Higher: more power at high motor speed, but warmer and louder. 4095 = no reduction.
Controller undervoltage4036 – 44 VBelow this battery voltage the controller reduces current and switches off. With 13 cells, 40 V is about 3.1 V per cell under load. Do not set it below the limit of the battery BMS.
Battery current3010 – 41 AMaximum current drawn from the battery; sets the peak power (current × voltage). More: more power, but more heat in motor and controller and more load on the gears.
Phase current7230 – 100 AMaximum current in the motor windings; sets the force when starting off and on hills.
Light always on (1 = on)00 – 1 1: the light is on from switch-on, the brake light keeps working. It can then no longer be switched off from the display.
Start ramp 2.5 s (1 = on)00 – 1 1: when starting from standstill, power rises over 2.5 s instead of jumping to full. After that the motor responds as usual. Applies again only after the bike has stood still for 2 s.
Shift sensor: throttle back instead of cutting out (1 = on)00 – 1 Applies to the shift sensor input (the same input as a brake sensor). 0: the motor cuts out completely while shifting, as from the factory. 1: the motor stays on, only the current is reduced. Use only if NO brake is connected to this input.
Shift sensor: throttle duration5000 – 2550 msMaximum time the current is reduced while the shift signal is present. If the signal lasts longer, the motor cuts out as usual. 0 = cut out immediately, as from the factory.
Shift sensor: current while throttled300 – 99 %How much current remains while throttled. 0 % = no load, but the motor stays on. Only effective when throttling is on.
Delay before restart after cut-out38496 – 384 msMinimum time the motor stays off after cutting out (shift sensor or pedal released). Shorter: full power returns sooner. Also applies at switch-on.
Ramp-up after restart (divisor per 10 ms)164 – 16 How fast the motor speed ramps up after a start: every 10 ms by 1/divisor of the gap. 4 = fast, 16 = gentle as from the factory. Also acts when starting from standstill; fast works best together with the start ramp.
Shift sensor: detection after samples31 – 3 After how many samples (10 ms each) a shift signal counts as real. Fewer: the motor cuts out faster when shifting. 1 = 20 to 30 ms, 3 = 40 to 50 ms as from the factory.
Level 1 current divisor (current = 200/value %)102 – 200 Current limit in level 1 = 200 divided by this value, in percent. 10 = 20 %, 5 = 40 %, 2 = 100 %.
Level 2 current350 – 100 %Current limit in level 2 as a percentage of the battery current.
Level 3 current550 – 100 %Current limit in level 3 as a percentage of the battery current.
Level 4 current700 – 100 %Current limit in level 4 as a percentage of the battery current. Level 5 always has 100 %.
Level 1 factor400 – 255 How strongly level 1 amplifies pedal pressure. Higher: more assistance for the same pressure.
Level 2 factor600 – 255 How strongly level 2 amplifies pedal pressure.
Level 3 factor800 – 255 How strongly level 3 amplifies pedal pressure.
Level 4 factor1000 – 255 How strongly level 4 amplifies pedal pressure.
Level 5 factor2000 – 255 How strongly level 5 amplifies pedal pressure. From the factory twice as strong as level 4.

What you need

A Windows computer, the programming cable and the free J-Link software.

AI-generated image
AI-generated image

Protected against operating errors

  • ✓Backup first. The firmware is backed up before every change.
  • ✓Verified writing. After writing, the program reads the data back and compares it byte by byte.
  • ✓Factory state at any time. One click enters the factory values again.

Important

Changes to the motor control are made at your own risk. The software is not intended for use on public roads. More power means more wear on the motor and gearbox.

Buy

After payment you receive your key by email and the download.

€49.95 incl. VAT

Payment by card, PayPal or bank transfer.